Electro Magnetic Induction And Alternating Currents Question 207

Question: A step down transformer is connected to 2400 volts line and 80 amperes of current is found to flow in output load. The ratio of the turns in primary and secondary coil is 20:1. If transformer efficiency is 100%, then the current flowing in the primary coil will be

Options:

A) 1600 amp

B) 20 amp

C) 4 amp

D) 1.5 amp

Show Answer

Answer:

Correct Answer: C

Solution:

  • $ \frac{I_{s}}{I_{p}}=\frac{n_{p}}{n_{s}};\frac{80}{I_{p}}=\frac{20}{1} $ or $ I_{p}=4amp. $


NCERT Chapter Video Solution